iX T12B-SC

12.1" graphic touch HMI with iX runtime and CODESYS soft control

  • 12.1" TFT-LCD touch screen
  • 1280 × 800 (16:10)

Important life cycle dates, read more -> Contact Print (PDF)

Facts

General description

Part number 640002201
Life cycle status
Warranty 1 year

Mechanical

Mechanical size 340 x 242 x 57 mm
Touch type Resistive type
Weight 2.5 kg
Housing material Powder coated aluminum

Power

Input voltage 24 VDC (18 - 32VDC)
Power consumption (max) 22 W
Input fuse Internal DC fuse, 3.15A slow

Display

Size diagonal 12.0 inch
Resolution 1280 X 800 pixels
Backlight LED backlight
Backlight life time 50,000 hrs
Backlight brightness 400 cd/m2
Backlight dimming Industrial
Display type TFT LCD

Serial communication

Number of serial ports 2 Port combined 9pin DSUB with dual pin out
Serial port 1 RS 232 (RTS/CTS)
Serial port 2 RS 485
Serial port 3 RS 232

Ethernet communication

Number of Ethernet ports 2
Ethernet port 1 1x10/100 Base-T (shielded RJ45)
Ethernet port 2 EtherCAT in CODESYS

Environmental

Operating temperature -10 to + 50 °C
Storage temperature -20 to + 70 °C
Shock 10G 11ms half sine
Vibration 0,7G RMS
Sealing front IP65
Sealing back IP20
Humidity <85 % non-condensed

Resources

Knowledge

File name Date
Beijer Electronics - Device Runtime and Compiler versions in CODESYS 2022-09-22 15:41:45
Number of ARTI connections to one TxA-SC, TxB-SC/SM 2022-12-07 13:59:22
TxA-SC, Max 3 Cyclic Task 2022-11-25 17:07:33
CODESYS - Declare persistent variables in GVL 2022-09-22 15:15:57
iX TxA/TxB SoftControl, How to set up ARTI controller in iX Developer to communicate with TxA/B SoftControl. 2022-09-22 15:16:13
TxA-SC - Modbus RTU/TCP slave error handling 2022-10-13 12:45:50
CoDeSys - TxA-SC, Trigger to start communication with a slave, Modbus RTU 2022-10-13 08:46:31
CoDeSys - TxA-SC timeout example (Modbus RTU) 2022-10-13 08:46:37
CoDeSys - TxA-SC, Modbus Com status 2022-10-13 08:46:31
CoDeSys - TxA-SC and NA-9173 / NA-9473, Timeout when more then 1 slave 2022-10-13 08:46:31
Codesys - iX TxA-SC, TxB-SC - Used Persistent Memory 2022-10-13 12:45:17
Codesys - Improvements in 3.5 SP2 2022-10-13 08:46:32
CODESYS - How to backup variable values (Recipe Manager) 2022-09-28 11:12:49
CoDeSys - Modbus RTU time setting, Bus Task and Application Task 2022-09-22 15:16:06
IX softcontrol \ softmotion project loading trough USB \ SD memory 2022-10-24 14:03:37
iX SoftControl/SoftMotion - Error message Read Timeout and Add Timeout 2022-10-25 15:55:09
iX - Transparent Mode Qnn serial through an iX panel with Serial/IP 2022-09-21 08:04:29
Knowledge: CODESYS 3.5 SP2 and released version of iX TxA SoftControl 2022-10-13 08:46:15
iX - How to enter the Service Menu to set a new IP address, calibrate touch etc 2022-12-08 11:31:45
CoDeSys and iX TxA SoftControl - Modbus status signals 2022-10-13 12:45:49
How to check what battery type your TxA is equipeed with 2022-11-25 18:27:20
EtherCAT installation guideline (cables, wiring, earth etc.) 2022-10-20 12:44:17
NA-9286, NA-9289, Change parameter in I/O moduls with IO Guide Pro 2022-10-12 15:23:06
TxB Softcontrol - Check communication status against ModbusTCP (NA-9289) 2022-10-12 16:31:35
Restart of Codesys EtherCAT slave using code 2022-10-13 12:45:50
IP setting on NA-9289 2022-10-12 15:27:10
Using Crevis ST5111 high speed counter as source to a Codesys FreeEncoder object 2022-10-12 15:22:34
Upgrading an existing SoftMotion project from v3.5.3.30 to v3.5.7.10 (TxB build 198) 2022-10-21 19:46:30

Configuration files

File name Date
iX TxA SoftControl, Device Description 2022-10-10 08:51:38
TxA-SC - Install Device description file in CoDeSys 2022-10-10 08:51:39

EOL information

File name Date
iX TxA-SC, iX TxB-SC End of Life 2022-10-10 08:51:49
TXX SM End of Life 2022-10-10 08:51:50

System program

File name Date
iX TxA-SC Image 1.11 2022-10-10 08:54:49
TxB-SC/ SM image 1.3 b202 2022-10-10 08:55:12

Manuals

File name Date
iX T7A Installation manuals 2022-10-10 08:39:30
iX T10A Installation manuals 2022-10-10 08:39:32
iX T4A Installation manuals 2022-10-10 08:39:27
iX T7B Installation manuals 2022-10-10 08:40:10
iX T15B Installation manuals 2022-10-10 08:39:51
iX T12B Installation manuals 2022-10-10 08:40:12

Product information

File name Date
TxB SoftControl LastMinutesNotes 2022-10-10 08:52:47
TxB SoftControl ReleaseNotes 2022-10-10 08:52:48

Information document

File name Date
iX - TxB SoftControl - Solution to the problem with Persistent Variables - EN 2022-10-10 08:52:03
Limited availability

iX T12B-SC

12.1" graphic touch HMI with iX runtime and CODESYS soft control


EOL - End Of Life:
2017-04-30

LTB - Last Time Buy:
2017-10-31

LTD - Last Time Delivery:
2018-01-31

LTR - Last Time Repair:
2021-12-31

Replacement Parts: