Facts
General description
Part number | 300-56603 |
Life cycle status | Limited |
Warranty | 1 year |
Certifications
General | CE, FCC, UL |
Mechanical
Mechanical size | 195.0 x 145.0 x 59.1 mm |
1million finger touch operations | |
Touch type | Resistive |
Cut-out size | 185.8 x 135.8 mm |
Weight | 1.26 kg |
Housing material | Plastic, Gray |
Power
Input voltage | 24V DC ± 15% |
Power consumption (max) | 24VDC, 20W |
Input fuse | Internal DC fuse |
Display
Size diagonal | 5.7" diagonal |
Resolution | 320x240 pixels |
Backlight | LED Backlight |
Backlight life time | 50000 hours |
Backlight brightness | 400 cd/m2 |
Backlight dimming | None |
Display type | Color TFT LCD |
Serial communication
Number of serial ports | 1 Port 9pin DSUB/1 Port 25 pin DSUB |
Serial port 1 | RS232/RS485 |
Serial port 2 | RS 232/RS422/Rs485 |
Expansion interface
SD card | CF |
USB | 1 USB Host, 1 USB Device |
Environmental
Operating temperature | -10°C to +60°C |
Storage temperature | 0°C to +50°C |
Shock | 10 G, 11 ms 3 times in each direction of X-, Y- and Zaxes |
Vibration | 0.5 mm displacement, 10-55 Hz, 2 hours per X-, Yand Z-axis directions |
Sealing front | IP65 |
Humidity | 20 - 90% RH non-condensed |
Resources
Information document
- HMI I/O Controller Product Information (PIEN259A)
- Important Notice: Battery Related Information (PI00154)
Brochures
- HMI I/O Controller leaflet (BREN515A)
- PWS Catalogues & Brochures
- PWS Series Brochure (BRxx500C)
- H-Series Brochure (BRxx460I)
Program examples/Quickstarts
- Using the HMI I/O Controller for H-T40m-PA (SUEN278A)
- LHT series Operator Panels Communicating with Siemens S7-200 PPI (SUEN275)
- Downloading a Project to an LHT series Operator Panel (SUEN276)
- H-Series Communicting with Siemens S7-200 PPI (SUEN252A)
- H-Series USB Functions
- H-series: Operator terminals communicating with Siemens S7-200 PPI (SUEN252A)
Software
- ADP & H-Designer v6.12 B200
- H-Designer V6.7.0 b193
- H-Designer V6.9.0 B196
- H-Designer V6.8 B195
- ADP V6.9.0-B196
- ADP6.13 B203
- ADP v6.10-B197
- X2 base ADP
Certificates
Drivers
Manuals
- HMI I/O Controller Installation Manual (MAEN987)
- Installation & Operation Guide PWS6560 (Chinese version)
- Installation & Operation Guide PWS6300 (Chinese version)
- Installation and Operation manual H-K30 (MA00823A)
- Installation & Operation Guide PWS6710
- PWS Operation & Installation Manuals
- Installation and Operation manual H-T40 (MAEN945B)
- H-Designer Reference Manual (MAEN822B)
- Installation and Operation manual H-T80 (MAEN833A)
- Installation and Operation manual H-T70 (MAEN922)
- Installation and Operation manual H-T60 (MAEN824E)
- Installation and Operation manual H-T50 (MA00825A)
- PWS Operation and Installation Manual (Eng ver)
- Installation and Operation manual H-T100 (MAEN834A)
- Reference manual for H-Designer (MAEN822B)
Knowledge
- Cable between the H-series and Alpha2
- Drawing for H-series pin converter 660062-07
- Data exchange in H-series?
- Collect data from a H-terminal?
- Driver The H-terminal's MPI address
- Driver - ControlLogix: Mapping DF1-addresses (PLC/SLC) in ControlLogix (KI00245)
- Download and upload application from USB or CF
- Download an application to an H-terminal using a modem connection?
- Communication problem H-series - DIP-switch settings
- Lonworks interface
- Driver H-Driver AB SLC5/03, 5/04: H-Series driver for Controllogix Ethernet
- Driver H-Driver AB SLC5/03, 5/04: Cable between H-terminal and AB SLC
- How many multi-link slaves can be connected to one master?
- How to Download to H-series via USB cable
- H-Series equipped with Web browser?
- H-series printer support
- H-Series Operator Terminals and ASCII communications
- H-series error codes
- HT80 and HT100 serial ports
- Communication problem H-series - DIP-switch settings
- CF and USB models for the H-series
- Hitech PWS920 - PDF
- Cables : Where find communication cable drawings for the H-series
- Calibrate H-terminal's touchscreen
- Examples of ladder logic in H-Series
- Programming software for PWS 920S
- Connecting to Allen-Bradley Micrologix 9-pin D-sub communications port
- Slow update/communication
- Driver H-Driver AB SLC5/03, 5/04: Which checksum-type is used in the driver
- Driver H-Driver Mitsubishi MELSEC-Q(CPU): H-series connected to Melsec Q-CPU
- Connecting H-Series Network terminal to Beckhoff CX1000 controller via ethernet
- Driver H-Driver Facon FB Series (RS232-RTS): Connect H-terminal to Fatek FBs-CB2
- Driver H-driver AB DH-485: DH+ driver for H-Series?
- Driver H-Driver Computer (as master): Computer As Master or Slave protocol
- Driver H-Driver ModBus Slave: Terminal as Modbus Master - bit addressing?
- Driver MODICON Modbus Master: Communication to Eurotherm Mini 8
- Driver H-Driver OMRON CJ1M: The syntax for bit addressing
- Driver H-Driver Simatic S7-300 (via MPI port): The H-terminal's MPI address
- Driver H-Driver Modicon TSX Micro: Modbus or Unitelway?
- Upload and convert PWS application
- Drivers in ADP / H-designer that support on-line simulation
- H-series - Is the internal memory volatile?
Drawings
- H-K30 Outline/Panel Cut-Out
- PWS6300 Outline/Panel Cut-Out
- H-T100 Outline/Panel Cut-Out
- H-T40m Outline/Panel Cut-Out
- H-T80 Outline/Panel Cut-Out
- H-T70 Outline/Panel Cut-Out
- H-T60 Outline/Panel Cut-Out
- H-T50 Outline/Panel Cut-Out
- PWS6400 Outline/Panel Cut-Out
- PWS5610 Outline/Panel Cut-Out
- PWS6500 Outline/Panel Cut-Out
- PWS6560 Outline/Panel Cut-Out
- PWS6600 Outline/Panel Cut-Out
- PWS6A00 Outline/Panel Cut-Out
- PWS6710 Outline/panel cut-out
- PWS6700 Outline/Panel Cut-Out
- PWS6620 Outline/Panel Cut-Out
- PWS6800 Outline/Panel Cut-Out
Limited availability
H-T60t-Pe
5.7'' graphic touch HMI
EOL - End Of Life:
2018-09-28
LTB - Last Time Buy:
2018-11-30
LTD - Last Time Delivery:
2019-02-28
LTR - Last Time Repair:
2020-02-28
Replacement Parts: