Facts
General description
Part number | 100-0974 |
Life cycle status | Active |
Warranty | 2 year |
Features
Protocol conversion | Yes |
Cloud connectivity | Yes |
HMI web server | Yes |
Local data base storage | Yes |
C# scripting | Yes |
Alarm server | Yes |
Certifications
General | CE, FCC, KCC |
Hazardous | ULC1D2 |
Marine | LR, ABS, BV, DNV GL |
Safety | UL 61010-2-201 |
Mechanical
DIN rail/mounting plate |
Power
Input voltage | 24VDC (18-32V DC) |
Power consumption (max) | 5W |
Input fuse | 3,14 AT |
CPU | i.MX6DualLite Dual Cortex-A9 1.0GHz 512kBL2cache |
RAM | 1 GB |
FLASH | 2GB SSD(eMMC), 1.5GB free for application |
Serial communication
Number of serial ports | 1 Port 9pin DSUB |
Serial port 1 | RS 232 (RTS/CTS) |
Serial port 2 | RS422/485 |
Serial port 3 | RS 485 |
Ethernet communication
Number of Ethernet ports | 2 |
Ethernet port 1 | 1x10/100 Base-T (shielded RJ45) |
Ethernet port 2 | 1x10/100 Base-T (shielded RJ45) |
Expansion interface
SD card | SD and SDHC |
USB | 1xUSB 2.0 500mA |
Environmental
Operating temperature | -10°C to +60°C |
Storage temperature | -20°C to +70°C |
Shock | 15g, half-sine, 11ms according to IEC60068-2-27 |
Vibration | 1g, according to IEC 60068-2-6, Test Fc |
Sealing front | IP20 |
Sealing back | IP20 |
Humidity | 5% – 85% non-condensed |
Altitude (max) | < 3000m |
Resources
Certificates
- DoC CE, EMC, RoHS Declaration of conformity X2 pro, X2 control, X2 marine , X2 web, Box 2 pro
- BoX2 pro (SC) / BoX2 extreme (SC) DNV - GL Type Approval Certificate
- BoX2 pro (SC), BoX2 extreme (SC) - ABS Type Approval Certificate
- DNV Type Approval Certificate BoX2 pro BoX2 extreme
- BoX2 pro (SC) / BoX2 extreme (SC), SAFE COMPASS DISTANCE INFORMATION,
- IECEx Certificate X2 extreme (SC) / BoX2 extreme (SC)
- BoX2 pro (SC) / BoX2 extreme (SC) - BV certificate for
- CE certification, BoX2 base - BoX2 pro - BoX2 extreme
- BoX2 base / BoX2 pro / BoX2 extreme FCC - Verification of compliance
Manuals
- BoX2 base v2 / pro (SC) (motion) / extreme (SC), Configuration and Image Manual, MAEN363
- Best Practice Image Update X2 HMI Panels 2.2, MAEN361 rev. B
- BoX2 pro (SC) Installation Manual, MAEN275
Drawings
Software
Product information
System program
- X2 pro / marine / BoX2 pro image V2.2 b1041 (Current version)
- X2 pro / X2 marine / BoX2 pro image V2.1 HF b909
- X2 pro / X2 marine / BoX2 pro, image V2.0 b773 (Obsolete)
- X2 pro / X2 marine / BoX2 pro image V1.5 (Obsolete)
Knowledge
- Box2 base / BoX2 pro (SC) / BoX2 extreme (SC), unknown IP \ reset \ reformat
- Best Practice Image update for X2 pro, X2 marine and BoX2 pro 2.1 HF, MAEN361
- BoX2 base / BoX2 pro (SC) / BoX2 extreme (SC) LED indication
- BoX2 Erase / Delete Project with USB
- Box2 Diagnostics, manual and LED
- X2 pro / X2 marine / BoX2 pro image V2.1 HF b909
Configuration files
Brochures
Program examples/Start-up
Limited availability
BoX2 pro
High-performance protocol converter/IIoT gateway/edge controller
EOL - End Of Life:
-
LTB - Last Time Buy:
-
LTD - Last Time Delivery:
-
LTR - Last Time Repair:
-
Replacement Parts: